Original Article · Open access
Minimum 10-year outcomes of highly cross-linked polyethylene in total hip arthroplasty for hip dysplasia: Effect of cup inclination in a matched comparative study
Abstract
Objectives: This study aims to compare the long-term outcome of highly cross-linked polyethylene (HXLPE) in hip dysplasia with osteonecrosis of the femoral head (ONFH) and evaluate the effect of cup inclination on HXLPE wear after total hip arthroplasty (THA) during a minimum 10-year follow-up.
Patients and methods: Between January 2000 and December 2012, a total of 124 patients who underwent primary THA for hip dysplasia or ONFH with a minimum 10-year follow-up were retrospectively analyzed. A total of 62 patients were successfully matched between the two groups (ONFH group, n = 62 and hip dysplasia group, n = 62). Primary outcomes included acetabular cup inclination, anteversion, and wear rates of HXLPE. Based on cup inclination, both groups were divided into three subgroups, classified as (1) ≤ 45°, (2) < 45° to < 50°, and (3) ≥ 55°. Secondary outcomes included the clinical score and radiographic findings of osteolysis, implant loosening, stress shielding, and heterotopic ossification. Kaplan-Meier curve and Cox regression test were used to compare the implant survivorship in the full cohort prior to exclusion and matching (178 hip dysplasia and 397 ONFH patients).
Results: There was no significant difference in survival rate without revision of prosthesis at 10-year between two groups (hip dysplasia: 94.7%, 95% confidence interval [CI]: 91.1% to 98.4% vs. ONFH: 95.7% (95% CI: 93.3% to 98.2%) (p = 0.4) Cup inclination was significantly steeper in the hip dysplasia group (47.6°, 95% CI: 46.0° to 49.3°) than in the ONFH group (43.9°, 95% CI: 42.3° to 45.5°) (p = 0.002). Steep cup inclination (> 55°) was significantly more frequent in the hip dysplasia group (11.3%, 7/62) than in the ONFH group (6.5%, 4/62; p = 0.006). However, wear rates of HXLPE were not significantly different between groups, and no correlation was found between cup inclination and HXLPE wear rate. No progressive osteolysis or prosthetic loosening was observed during follow-up.
Conclusion: Although patients with hip dysplasia demonstrated a steeper mean cup inclination and a higher incidence of steep cup positioning compared to those with ONFH, implant survivorship remained comparable between groups in the overall cohort. In the matched cohort analysis, HXLPE wear rates and clinical outcomes were also comparable between the groups. These findings suggest that, despite technical challenges in acetabular positioning, the use of HXLPE in THA for hip dysplasia provides satisfactory long-term performance and may alleviate concerns regarding cup inclination-related wear.
* These authors contributed equally to this work.
Declarations
Author Contributions
B.W.M., K.J.L.: Conception and design of study; B.C.C., H.S.S.: Acquisition of data; B.C.C., K.J.L.: Analysis and/or interpretation of data; B.C.C., K.J.L., B.W.M.: Drafting the manuscript; K.J.L., B.W.M.: Revising the manuscript critically for important intellectual content.
Conflict of Interest
The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.
Financial Disclosure
The authors received no financial support for the research and/or authorship of this article.
Data Sharing Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
AI Disclosure
The authors declare that artificial intelligence (AI) tools were not used, or were used solely for language editing, and had no role in data analysis, interpretation, or the formulation of conclusions. All scientific content, data interpretation, and conclusions are the sole responsibility of the authors. The authors further confirm that AI tools were not used to generate, fabricate, or ‘hallucinate’ references, and that all references have been carefully verified for accuracy.
References
- Turan K, Kezer M, Çamurcu Y, Uysal Y, Kızılay YO, Ucpunar H, et al. Intraoperative neurophysiological monitoring in total hip arthroplasty for crowe types 3 and 4 hips. Clin Orthop Surg 2023;15:711-7. DOI: 10.4055/cios22371.
- Tolunay T, Baymurat AC, Çalta MŞ, Atalar H. Cakirgil method in the surgical treatment of older children with developmental dysplasia of the hip: Mid-term follow-up results of 17 hips and literature review. Jt Dis Relat Surg 2024;35:202-8. DOI: 10.52312/jdrs.2023.1510.
- Tateda K, Nagoya S, Suzuki D, Kosukegawa I, Yamashita T. Acetabular morphology in patients with developmental dysplasia of the hip with high dislocation. Hip Pelvis 2021;33:25-32. DOI: 10.5371/hp.2021.33.1.25.
- Rogers BA, Garbedian S, Kuchinad RA, Backstein D, Safir O, Gross AE. Total hip arthroplasty for adult hip dysplasia. J Bone Joint Surg Am 2012;94:1809-21. DOI: 10.2106/JBJS.K.00779.
- Ueno T, Kabata T, Kajino Y, Ohmori T, Yoshitani J, Tsuchiya H. Three-dimensional host bone coverage required in total hip arthroplasty for developmental dysplasia of the hip and its relationship with 2-dimensional coverage. J Arthroplasty 2019;34:93-101. DOI: 10.1016/j.arth.2018.09.082.
- Yon CJ, Lee KJ, Choi BC, Suh HS, Min BW. The validation of two-dimensional and three-dimensional radiographic measurements of host bone coverage in total hip arthroplasty for hip dysplasia: A comparison with intraoperative measurements. J Clin Med 2023;12:6227. DOI: 10.3390/jcm12196227.
- Wang L, Thoreson AR, Trousdale RT, Morrey BF, Dai K, An KN. Two-dimensional and three-dimensional cup coverage in total hip arthroplasty with developmental dysplasia of the hip. J Biomech 2013;46:1746-51. DOI: 10.1016/j.jbiomech.2013.03.025.
- Galea VP, Laaksonen I, Donahue GS, Fukui K, Kaneuji A, Malchau H, et al. Developmental dysplasia treated with cementless total hip arthroplasty utilizing high hip center reconstruction: A minimum 13-year follow-up study. J Arthroplasty 2018;33:2899-905. DOI: 10.1016/j.arth.2018.04.037.
- Della Valle AG, Padgett DE, Salvati EA. Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 2005;13:455-62. DOI: 10.5435/00124635-200511000-00005.
- Inori F, Ohashi H, Yo H, Okajima Y, Matsui Y, Shintani K. Accuracy of cup height and medialization in THA for dysplastic hip osteoarthritis using an imageless navigation system. Orthopedics 2012;35:7-12. DOI: 10.3928/01477447-20120919-50.
- Park JW, Park JH, Kim HS, Lee YK, Han KY, Ha YC, et al. Optimization of acetabular cup abduction by adjusting pelvic pitch. Clin Orthop Surg 2024;16:16-22. DOI: 10.4055/cios21219.
- Patil S, Bergula A, Chen PC, Colwell CW Jr, D'Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am 2003;85:56-63. DOI: 10.2106/00004623-200300004-00007.
- Murray PJ, Hwang KL, Imrie SN, Huddleston JI 3rd, Goodman SB. Polyethylene wear and osteolysis is associated with high revision rate of a small sized porous coated THA in patients with hip dysplasia. J Arthroplasty 2014;29:1373-7. DOI: 10.1016/j.arth.2014.02.027.
- Georgiades G, Babis GC, Kourlaba G, Hartofilakidis G. Effect of cementless acetabular component orientation, position, and containment in total hip arthroplasty for congenital hip disease. J Arthroplasty 2010;25:1143-50. DOI: 10.1016/j.arth.2009.12.016.
- Tian JL, Sun L, Hu RY, Han W, Tian XB. Correlation of cup inclination angle with liner wear for metal-on-polyethylene in hip primary arthroplasty. Orthop Surg 2017;9:186-90. DOI: 10.1111/os.12337.
- Min BW, Cho CH, Son ES, Lee KJ, Lee SW, Song KS. Highly cross-linked polyethylene in total hip arthroplasty in patients younger than 50 years with osteonecrosis of the femoral head: A minimum of 10 years of follow-up. J Arthroplasty 2020;35:805-10. DOI: 10.1016/j.arth.2019.10.021.
- Min BW, Bae KC, Cho CH, Son ES, Lee KJ, Lee SW. Highly cross-linked polyethylene in cementless total hip arthroplasty in patients with previous acetabular fractures: A minimum 5-year follow-up study. Indian J Orthop 2020;54:239-45. DOI: 10.1007/s43465-020-00137-z.
- Tsukamoto M, Ohnishi H, Mori T, Kawasaki M, Uchida S, Sakai A. Fifteen-year comparison of wear and osteolysis analysis for cross-linked or conventional polyethylene in cementless total hip arthroplasty for hip dysplasia-a retrospective cohort study. J Arthroplasty 2017;32:161-5.e1. DOI: 10.1016/j.arth.2016.06.008.
- Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 1995;77:432-9. DOI: 10.2106/00004623-199503000-00013.
- Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Müller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 1990;72:161-8.
- Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am 1973;55:1629-32.
- Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of poroussurfaced femoral components. Clin Orthop Relat Res. 1990;(257):107-28.
- DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976;(121):20-32.
- Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: A radiographic analysis of loosening. Clin Orthop Relat Res 1979;(141):17-27.
- Caylak R, Ors C, Togrul E. Minimum 10-year results of cementless ceramic-on-ceramic total hip arthroplasty performed with transverse subtrochanteric osteotomy in crowe type IV hips. J Arthroplasty 2021;36:3519-26. DOI: 10.1016/j.arth.2021.05.035.
- D'Lima DD, Chen PC, Colwell CW Jr. Optimizing acetabular component position to minimize impingement and reduce contact stress. J Bone Joint Surg Am 2001;83:87-91. DOI: 10.2106/00004623-200100022-00005.
- Korduba LA, Essner A, Pivec R, Lancin P, Mont MA, Wang A, et al. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing. Am J Orthop (Belle Mead NJ) 2014;43:466-71.
- Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty 1998;13:621-6. DOI: 10.1016/s0883-5403(98)80003-x.
- Watts CD, Abdel MP, Hanssen AD, Pagnano MW. Anatomic hip center decreases aseptic loosening rates after total hip arthroplasty with cement in patients with crowe type-II dysplasia: A concise follow-up report at a mean of thirtysix years. J Bone Joint Surg Am 2016;98:910-5. DOI: 10.2106/JBJS.15.00902.
- Higuchi Y, Seki T, Hasegawa Y, Morita D, Komatsu D, Takegami Y, et al. Comparison of cementless total hip arthroplasty survivorship between metal-on-highly crosslinked polyethylene and ceramic on ceramic bearings: A case control study with a 5-9-year follow-up. Orthop Traumatol Surg Res 2018;104:663-9. DOI: 10.1016/j.otsr.2018.04.016.
