Skip to main content
JDRS · Open access journal

Original Article · Open access

The greater sciatic notch-based transcolumnar magic screw trajectory in the acetabulum: An anatomical guide

PDF Cite this article

Pelin İsmailoğlu

Department of Anatomy, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye

ORCID: 0000-0002-2631-496X

Cengiz Kazdal

Department of Orthopedics and Traumatology, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye

ORCID: 0000-0002-2121-4580

Emrehan Uysal

Independent Researcher, Student, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye

ORCID: 0009-0004-1301-1048

Alp Bayramoğlu

Department of Anatomy, Acıbadem Mehmet Ali Aydınlar University, İstanbul, Türkiye

ORCID: 0000-0002-2801-5293

Abstract

Objectives: This study aims to define the greater sciatic notch (GSN)-based transcolumnar “magic screw” corridor in the acetabulum and to assess its morphometric characteristics and anatomical feasibility according to quadrilateral plate (QP) morphology.

Materials and methods: Between November 2025 and January 2026, three-dimensional morphometric analysis was performed on pelvic CT reconstructions of 90 adults (180 acetabulae) with intact pelvic bones and no evidence of hip or pelvic pathology. Using Mimics, pelvic models were reconstructed and a virtual 6.5-mm cannulated screw was advanced from the midpoint of the GSN toward the anterior column along a transcolumnar intraosseous trajectory. Bilateral trajectory length, angulation, and QP thickness were recorded. Differences by sex and side, age associations, and anatomical feasibility (“easy” versus “hard”) were analyzed based on anatomical corridor constraints.

Results: Of the patients included in the study, 42 were male and 48 were female with a mean age of 49.88 ± 17.18 (range, 19 to 86) years. The defined GSN-based transcolumnar screw corridor was anatomically feasible in 94.44% of cases. Mean posterior acetabular screw length was 74.16 ± 7.49 mm right and 73.21 ± 6.90 mm left. Mean GSN entry segment length was 22.95 ± 4.14 mm right and 23.48 ± 4.34 mm left. Mean acetabular screw angles were 125.86° ± 6.05° right and 124.26° ± 5.24° left, with a small but significant right-left difference (p = 0.004). The QP morphology demonstrated substantial variability: mean maximum thickness was 14.87 ± 2.75 mm right and 14.77 ± 2.82 mm left, while minimum thickness was 3.46 ± 1.37 mm right and 3.48 ± 1.32 mm left. Men had significantly greater superior and posterior acetabular screw lengths and markedly thicker QP parameters compared with women (all p ≤ 0.027), with large effect sizes for QP thickness (d > 1.0).

Conclusion: A GSN-based transcolumnar magic screw corridor appears anatomically feasible in most adult pelves and provides a quantifiable intraosseous trajectory reaching both acetabular columns. Quadrilateral plate thickness emerges as the main anatomical limiting factor, particularly in female pelves and in cases categorized as corridor-constrained.

Declarations

Author Contributions

P.İ., C.K.: Idea/concept, literature review, references and fundings; C.K.: Design; A.B.: Control/ supervision; P.İ., E.U.: Data collection and/or processing; P.İ.: Analysis and/or interpretation, writing the article, other; C.K., A.B.: Critical review; P.İ, A.B.: Materials.

Conflict of Interest

The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Financial Disclosure

The authors received no financial support for the research and/or authorship of this article.

Data Sharing Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

AI Disclosure

The authors declare that artificial intelligence (AI) tools were not used, or were used solely for language editing, and had no role in data analysis, interpretation, or the formulation of conclusions. All scientific content, data interpretation, and conclusions are the sole responsibility of the authors. The authors further confirm that AI tools were not used to generate, fabricate, or ‘hallucinate’ references, and that all references have been carefully verified for accuracy.

References

  1. Qi X, Zhang X, Zhang Q, Zhang Y, Huang S, Lv Y, et al. Clinical efficacy and biomechanical analysis of robotic internal fixation with percutaneous screws in the treatment of both-column acetabular fractures. Sci Rep 2025;15:22908. DOI: 10.1038/s41598-025-06168-6.
  2. Alsheikh KA, Alzahrani AM, Alshehri AS, Alzahrani FA, Alqahtani YS, Alhumaidan MI, et al. Clinical outcomes of percutaneous screw fixation of acetabular fracture: A minimally invasive procedure. J Taibah Univ Med Sci 2022;18:279-86. DOI: 10.1016/j.jtumed.2022.09.015.
  3. Gänsslen A, Lindahl J, Lindtner RA, Krappinger D, Staresinic M. Special screw corridors and imaging in pelvic ring trauma. Arch Orthop Trauma Surg 2025;145:110. DOI: 10.1007/s00402-024-05610-0.
  4. Lu H, Gong X, Xuan C, Lu Q. CT Imaging anatomical study of percutaneous magic screw fixation for acetabular posterior column fracture. Research Square [Preprint] 2022. DOI: 10.21203/rs.3.rs-1271947/v1.
  5. Serra M, Solano A, Godinho M, Mereddy P, Baron ML, Mauffrey C. Acetabular reconstruction: from fracture pattern to fixation-part 2. Injury 2025;56:112781. DOI: 10.1016/j.injury.2025.112781.
  6. Solano A, Serra M, Mereddy P, Godinho M, Le Baron M, Mauffrey C. Acetabular reconstruction: From fracture pattern to fixation - part 1. Injury 2025;56:112578. DOI: 10.1016/j.injury.2025.112578.
  7. Freude T, Gänsslen A, Krappinger D, Lindahl J. Quadrilateral plate fractures. Arch Orthop Trauma Surg 2024;145:51. DOI: 10.1007/s00402-024-05698-4.
  8. Guo J, Dong W, Zhou Y, Hu J, Ye P, Chen W, et al. Differences in fixation to young and elderly quadrilateral surfaces with Anatomic Quadrilateral Surface Plate (AQSP) based on cortical thickness morphological results. J Orthop Surg Res 2022;17:143. DOI: 10.1186/s13018-022-03027-2.
  9. Li J, Li Z, Wang X, Zhang G, Peng Y, Zhang S, et al. Establishment of fluoroscopy views and standardized procedure of percutaneous magic screw insertion for acetabulum fractures. BMC Musculoskelet Disord 2018;19:332. DOI: 10.1186/s12891-018-2228-y.
  10. Gupta A, Bansal P, Kumar V, Aggarwal S. Quadrilatral plate stabilization: Conventional reconstruction plate or anatomical plate: A systematic review and meta-analysis. J Clin Orthop Trauma 2025;69:103120. DOI: 10.1016/j.jcot.2025.103120.
  11. Egli RJ, Keel MJB, Cullmann JL, Bastian JD. Secure screw placement in management of acetabular fractures using the suprapectineal quadrilateral buttress plate. Biomed Res Int 2017;2017:8231301. DOI: 10.1155/2017/8231301.
  12. Sun Y, Chen J, Li X, Lv F. Safe passage analysis for both column screw fixation technique in posterior column acetabular fractures. Sci Rep 2025;15:44932. DOI: 10.1038/s41598-025-29543-9.
  13. Zheng L, Hao J, Hu CJ, Shen X, Yang G, Zeng G, et al. Antegrade insertion of full-length ramus screws for the treatment of pelvic and/or acetabular fracture. Injury 2025;56:112669. DOI: 10.1016/j.injury.2025.112669.
  14. Öztürk V, Bilgili MG. Fluoroscopy-assisted identification of the individual optimal antegrade entry point of the anterior column fixation corridor in pelvic and acetabular surgery: A novel perspective. J Orthop Surg Res 2025;20:635. DOI: 10.1186/s13018-025-06027-0.
  15. Chanbour H, Roth SG, Chen JW, Uppuganti S, Nyman JS, Ali MA, et al. Do iliac screws placed close to the sciatic notch have greater pullout strength? Oper Neurosurg 2024;27:549-56. DOI: 10.1227/ons.0000000000001159.
  16. Collinge CA, Ziran NM, Coons DA. Relationship between the superior gluteal vessels and nerve at the greater sciatic notch. Orthopedics 2015;38:e929-33. DOI: 10.3928/01477447-20151002-62.
  17. van der Merwe JF, Erasmus LJ, van der Merwe W, Ellis JA. Obtaining optimum screw placement for revision acetabular prostheses using the sciatic notch as reference. Transl Res Anat 2021;24:100133. DOI: 10.1016/j.tria.2021.100133.
  18. Issack PS, Helfet DL. Sciatic nerve injury associated with acetabular fractures. HSS J 2009;5:12-8. DOI: 10.1007/s11420-008-9099-y.
  19. Field AP. Discovering Statistics Using IBM SPSS Statistics. 6th ed. London: SAGE Publications Ltd; 2024.
  20. George D, Mallery P. IBM SPSS Statistics 29 Step by Step: A Simple Guide and Reference. 18th ed. New York: Routledge; 2024.
  21. Tabachnick BG, Fidell LS, Ullman JB. Using multivariate statistics. Vol 5. pearson Boston, MA; 2007.
  22. Musikachart P, Ariyawatkul T, Wongcharoenwatana J, Piamthipmanas T, Chanchoo S, Eamsobhana P. Intraobserver and inter-observer reliability of shaft condylar angle and lateral capitellohumeral angle: Evaluation based on reliability in different ages and levels of experience. Orthop Surg 2019;11:467-73. DOI: 10.1111/os.12489.
  23. Starr AJ, Walter JC, Harris RW, Reinert CM, Jones AL. Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess "lateral compression type II" pelvic fractures). J Orthop Trauma 2002;16:116-23. DOI: 10.1097/00005131-200202000-00008.
  24. Caviglia H, Mejail A, Landro ME, Vatani N. Percutaneous fixation of acetabular fractures. EFORT Open Rev 2018;3:326- 34. DOI: 10.1302/2058-5241.3.170054.
  25. Öztürk V, Kaya B, Çelik T, Çelik M, Kural C, Bilgili MG. Is the innovative both column screw fixation technique a biomechanical game-changer in the fixation of acetabular posterior column fractures? Int Orthop 2025;49:2271-80. DOI: 10.1007/s00264-025-06604-2.
  26. Keating EM, Ritter MA, Faris PM. Structures at risk from medially placed acetabular screws. J Bone Joint Surg Am 1990;72:509-11.
  27. Shon WY, Gupta NR, Deshmukh SN, Garud AB, Theeppainthan P, Lee KS. Prevention of pernicious vascular event: Acetabular component screw impinging on external iliac vessels - a unique case report. J Orthop Case Rep 2023;13:121-6. DOI: 10.13107/jocr.2023.v13.i10.3960.